PROCESSOR
OPTIONS |
| Processor |
One 650-MHz UltraSPARCŪ IIi processor |
| Cache |
Primary: 16 KB data and 16 KB instruction
on chip
Secondary: 512 KB external |
|
MAIN MEMORY |
| Two PC-133 DIMM slots holding up
to 2GB memory |
|
STANDARD
INTERFACES |
| Network |
Two 10/100/1000-Mbps Ethernet ports |
| Serial |
Two RS-232 serial ports |
| Expansion Capability |
Up to sixteen Blade Servers in a single
Sun Fire B1600 Blade System Chassis |
|
MASS
STORAGE AND MEDIA |
| Internal Disk |
One 30GB 2.5-in., 5400 RPM, Ultra ATA 100 24X7 server class
drive with 16 MB buffer and 12 ms average latency |
| External Storage |
Sun StorEdge 3310 NAS Array |
| SOFTWARE |
| Operating system |
Solaris 8 12/02 or later operating system
Solaris 9 4/03 or later operating system |
|
ENVIRONMENT |
| Power Supply |
Input Rating: (Sun Blade Platform)
110-240
V AC, 47-63 Hz
12A
max at 110V, 6A max at 230V
Average Power Consumption: (Sun Blade Platform)
16
X SPARCŪ Blades + 2 switches = 650W |
| Temperature |
Operating: 5°C to 35°C (41° F to 95° F)
Non-operating: -40°C to 65°C (-40° F to 149° F) |
| Relative Humidity |
Operating: 10% to 90%
Non-operating: 93% |
| Elevation |
Up to 3000m, (70kPa) |
|
REGULATIONS |
| Meets or exceeds the following
requirements: |
| Safety |
IEC 60950 (C22.2-60950) (EN60950)
(UL60950) |
| Certification Statements and Marks |
CULus, TuV-GS, TuV-S, CCCs&e, C-tick, VCCI-A, BSMI-T,
MIC, CE, ICES-A, FCC-A |
| Emissions and Immunities: |
|
| RF Radiated Emissions |
CISPR22 (EN55022), Class B European Union
FCC Part 15, Class B USA, Industry of Canada |
| Conducted Emissions |
CISPR22 (EN55022), Class B European Union
FCC Part 15, Class B USA, Industry of Canada |
| Harmonic Emissions |
IEC 61000-3-2:2000 (No Limits) European
Union |
| Voltage Flicker |
IEC 61000-3-3:1995/A1:2001 (No Limits) |
| ESD Immunity |
CISPR 24 (EN55024; 8kV Contact, 15kV Air)
IEC 61000-4-2 |
| RF Field Immunity |
CISPR 24 (EN55024, 10V/m) IEC 61000-4-3 |
Electric Fast
Transient/Burst Immunity |
CISPR 24 (EN55024; 1kV I/O, 2kV Power) IEC
61000-4-5 |
| Surge Immunity |
CISPR 24 (EN55024; 1kV I/O, 1kV Power L-L, 2kV Power L-G)
IEC 61000-4-5 |
| RF Conducted Immunity |
CISPR 24 (EN55024; 3V I/O and Power) IEC
61000-4-6 |
|
DIMENSIONS
AND WEIGHTS |
| Blade |
|
| Height |
114.8 mm (4.5 in.) |
| Depth |
338.7 mm (12.5 in.) |
| Width |
26 mm (1 in.) |
| Weight |
1.15 kg (2.5 lb.) |
| Chassis |
|
| Height |
134.4 mm (5.25 in.), 3U |
| Depth |
681 mm (26.5 in.) |
| Width |
448 mm (17.2 in.) |
| Weight |
18.5 kg (53.5 lb.), with no Blade; 42.5 kg (93.5 lb.), fully
loaded with 16 Blades |
| Rackmount |
Fits into 19-, 23-, 24-in., and 600 mm
standard racks |