Up to 4 GB of memory
|
|
|
Up to 2 disk drives
|
|
|
Main memory
|
|
Up to 4 GB of memory
|
|
|
Standard Interfaces
|
|
Ethernet
|
10/100-Mbps BaseT Ethernet port
|
|
SCSI
|
80 MB/sec. UltraSCSI-2 SE/LVD port
|
|
Serial
|
Two RS-232C/RS-423 serial ports (RJ45)
|
|
USB
|
Two OHCI-compliant ports
|
|
Expansion bus
|
Single full-length 32-bit, 33-MHz PCI slot compliant
with PCI specification version 2.1
|
|
System Configuration reader and card
|
Rear accessible for transfer of system configuration
information, including host ID
|
|
Mass Storage
|
|
Internal disk
|
Up to two 3.5-in. x 1-in. 73-GB 10Krpm SCSI
hot-swappable, front-accessible disks
|
|
DVD-ROM
|
8X SuperSlim DVD-ROM (optional)
|
|
External storage
|
(Optional)
- Sun StorEdge A1000/D1000 array
- Sun StorEdge 3120 SCSI array
- Sun StorEdge 3300 SCSI array
- Sun StorEdge S1 array
- Sun StorEdge D2 array
- Sun StorEdge T3 array
|
|
Internal CD-ROM
|
40X SuperSlim CD-ROM (optional)
|
|
Software
|
|
Operating System
|
Solaris 8 Operating System (2/02) Update 7 or later
Solaris 9 Operating System
|
|
Languages
|
Java programming language, all other standard
Sun-supported languages
|
|
Networking
|
ONC/NFS, TCP/IP, SunLink OSI, MHS, IPX/SPX, DCE software
|
|
System Management
|
Sun Management Center, SNMP/MIBS, SunVTS, SRS Ready
software
|
|
Network Management
|
Sun Java System Web Server, Sun Java System Active
Server Pages, and Apache HTTP server software
|
|
High Availability
|
Sun Cluster 3.0 software
|
|
|
|
DC power
|
-40/-75 V DC
|
|
Power Input
|
2A/1A
|
|
Operating
|
5° C to 40° C (41° F to 104° F), 20% to 80%
relative humidity, noncondensing
|
|
Nonoperating
|
-40° C to 70° C (40° F to 158° F), 10% to
95% relative humidity, noncondensing
|
|
Short-Term operating
|
(96 consecutive hours) -5° C to 55° C (23° F
to 122° F), 5% to 90% relative humidity,
noncondensing
|
|
Altitude
|
-300 m to +3000 m
|
|
Acoustic Noise
|
Less than 60 dBA (GR-63-Core Test Method)
|
|
Seismic
|
Meets GR-63-CORE requirements for earthquake
risk Zone 4
|
|
ETSI
|
ETS 399-19-2-3, Table 3.1, Climatic
|
|
BTU/hr
|
Maximum: 550
Minimum: 335 (nominal)
|
|
|
|
Meets or exceeds the following requirements:
|
|
Safety
|
UL 1950/CSA C22.2 No. 950, EN 60950 (73/23/IEEC),
IEC 950
|
|
Emissions
|
CFR Title 47 FCC Part 15, EN 55022 (80/336/EEC)
|
|
Certification
|
Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CD Mark (93/68/EEC), FCC Authorized Class A
|
|
Telecom Environment Certification
|
Telcordia: GR-63-CORE, GR-1089-CORE,
TR-NWT-00295, SR 3580 NEBS Level 3
|
|
|
|
Height
|
44.0 mm (1.7 in.)
|
|
Width
|
437.2 mm (17.2 in.)
|
|
Depth
|
478.0 mm (18.8 in.)
|
|
Weight
|
9.0 kg (19.8 lb.)
|
|
Enclosure
|
Fits 19-, 23-, 24-in., and 600 mm racks
|