Standard Interfaces
|
|
Network
|
Two 10/100/1000Base-T Ethernet ports
|
|
Network Management
|
One 10Base-T Ethernet port
|
|
Serial management
|
One TIA/EIA-232-F (RJ45) port
|
|
Serial
|
One TIA/EIA-232-F asynchronous (DB9) port
|
|
SCSI
|
One Ultra320 SCSI multimode (SE/LVD) port
|
|
USB
|
Four OHCI 1.0-compliant interfaces, each
supporting dual speeds of 12 Mbps and 1.5 Mbps
|
|
Expansion bus
|
Six 64-bit, full-length, PCI 2.2-compliant
expansion slots:
- Three 33-MHz or 66-MHz 3.3V slots
- Three 33-MHz 5V slots
|
|
System Configuration reader and card
|
Front accessible to transfer system configuration
information, including host ID, MAC address, and
NVRAM
|
|
Alarms
|
Four fail-safe, dry contact alarms (critical,
major, minor, and user-defined)
|
|
Mass Storage
|
|
|
Internal disk
|
Up to four hot-swappable, 73-GB, 15K-rpm Ultra320
SCSI disks
|
|
Removable media
|
Optional DVD-RW or DVD-ROM
|
|
External disk
|
Support provided for the following storage arrays:
- Sun StorEdge 3000 series
- Sun StorEdge A1000/D1000
- Sun StorEdge D240
- Sun StorEdge T3 enterprise array
- Sun StorEdge T3 workgroup array
- Sun StorEdge D2
- Sun StorEdge S1
- Sun StorEdge A5200
- Sun StorEdge 6000 series
- Sun StorEdge 3900 series
- Sun StorEdge 6900 series
- Sun StorEdge 9900 series
|
|
External tape
|
Support provided for the following tape drives and
tape automation:
- Sun StorEdge 4mm DDS-3 Unipack
- Sun StorEdge 4mm DDS-4 Unipack
- Sun StorEdge SDLT 320 Desktop Tape Drive
- Sun StorEdge LTO 2 Desktop Tape Drive
- Sun StorEdge L8 Tape Autoloader
- Sun StorEdge L9 Tape Autoloader
- Sun StorEdge L25-LVD versions
- Sun StorEdge L100-LVD versions
- Sun StorEdge L180
|
|
Software
|
|
Operating System
|
- Solaris 8 Operating System (7/03) or later
- Solaris 9 Operating System (12/03) or later
|
|
Languages
|
C/C++, Fortran, Java programming language, and all
other standard Sun-supported languages
|
|
Networking
|
ONC, NFS, TCP/IP, SunLink, OSI, MHS, X.25, IPX/SPX
software
|
|
Management
|
SunVTS, SRS Net Connect, SRM, ALOM software,
Watchdog Timer
|
|
High Availability
|
Sun Cluster 3.x software
|
|
Power Supplies
|
|
The Netra 440 server comes with four hot-pluggable
AC or DC power supplies with separate power cords;
a minimum of two supplies are required for normal
system operation. The following rates are based on
use of two power supplies.
|
|
Maximum DC input
|
1040W
|
|
Maximum AC input
|
1000W
|
|
Maximum output (AC and DC)
|
800W
|
|
Maximum power consumption
|
Maximum power consumption (AC and DC): 660W
(typical)
|
|
Input current
|
Input current (DC): 23A
Input current (AC): 11 A @90V AC
|
|
Environment
|
|
|
DC power
|
-40V to -75V DC (range)
-48V DC or -60 V DC (nominal)
|
|
AC power
|
90-264V AC (47-63Hz)
|
|
Operating temperature
|
5° C to 40° C (41° F to 104° F) 5% to 85%
relative humidity, noncondensing short term -5° C
to 55° C (23° F to 131° F) 5% to 90% relative
humidity, noncondensing, but not to exceed 0.024
kg water/kg dry air (0.053 lb water/2.205 lb dry
air)
|
|
Nonoperating temperature
|
-40° C to 70° C (-40° F to 158° F), up to 93%
relative humidity noncondensing, 38° C (100.4°
F) max wet bulb
|
|
Altitude
|
Operating: up to 3000 m
Nonoperating: up to 12,000 m
|
|
Acoustic Noise
|
Declared noise emissions in accordance with ISO
9296: 7.0 B (operating and idling)
|
|
ETSI
|
EN 300 019-2-1, Table 3.1 and Table 3.1E, except
for:
- -5º C Cold start
- Condensing humidity
- Rain
|
|
Seismic
|
Meets GR-63-CORE requirements for earthquake risk
Zone 4
|
|
Regulations
|
|
Meets or exceeds the following requirements:
|
|
Safety
|
IEC60950, UL/CSA60950, EN60950
|
|
RFI/EMI
|
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN
300-386:2001 V1.3.1, ICES-003
|
|
Immunity
|
EN55024
|
|
Certification
|
Safety: cULus Mark, TUV GS Mark, CE Mark, CCC,
GOST R
EMC: CE Mark (93/68/EEC), FCC authorized Class
A, VCCI, BSMI, CTICK, MIC
|
|
Telecom Environment Certification
|
Telcordia GR-63 CORE, GR-1089-CORE, SR 3580 NEBS
Level 3
|
| Dimensions and Weight |
|
|
Height
|
222 mm (8.75 in.)
|
|
Width
|
440 mm (17.32 in.) including bezel
|
|
Depth
|
495 mm (19.5 in.) overall maximum depth
476 mm (18.75 in.) front bezel tangent to
rear I/O panel
|
|
Weight
|
37 kg (81.6 lb) fully configured with PCI
cards and rack kit
36 kg (79.4 lb) without PCI cards and rack
kit
|
|
Enclosure
|
Fits into a standard 19-in.-wide rack. 19-in.,
2-post and 4-post rack kit is included.
Additional rack kits available include 23-in.,
2-post, 600 mm x 600 mm and 19-in., 4-post,
slide adjustable up to 800 mm.
|