Specification |
| |
| Processor
Options |
| Processor |
900 MHz
UltraSPARC III Cu |
| Architecture |
Superscalar
SPARC V9 |
| Processor
modules |
One or two
dual-processor memory modules |
| Cache (on
chip) |
64 KB data
and 32 KB instruction |
| Secondary
cache (L2) |
8 MB
external |
| System
interconnect |
Sun
Fireplane interconnect, 9.6 GBps |
| Main
Memory |
| A
system maximum of 32 GB when configured with four processors |
| Standard/Integrated
Interfaces |
| Network |
Two
10/100/1000-Mbps Ethernet ports |
| I/O |
FC-AL disk
controller, two USB ports |
| Serial |
RJ45 serial
port |
| Expansion
capability |
Six 64-bit
PCI slots compliant with PCI specification Revision 2.1:
- Two at 66 MHz, 3.3 volts
- Four at 33 MHz, 5 volts
|
| Mass
Storage and Media |
| Host
adapters |
Internal IDE
to support the internal DVD-ROM drive |
| Internal
disk |
Two 3.5-inch
x 1.0-inch 10,000 RPM FC-AL disks, 36 GB drive (73 GB drives
also supported)
|
| Internal DVD |
DVD-ROM
drive |
| External
disk compatibility |
Sun StorEdge
MultiPack systems
- Sun StorEdge A1000
- Sun StorEdge D1000
- Sun StorEdge A5200
- Sun StorEdge T3
- Sun StorEdge D2
- Sun StorEdge S1
- Sun StorEdge 3900/6900
- Sun StorEdge 9900
|
| External
tape system compatibility |
SCSI tape
devices via a SCSI host bus adapter:
- Sun StorEdge 12 GB DDS-3 UniPack
- Sun StorEdge DDS-3 Autoloader FlexiPack
- Sun StorEdge 20 GB DDS-4 UniPack
- Sun StorEdge DL T8000 FlexiPack
- Sun StorEdge L9 tape autoloader
- Sun StorEdge L20 tape library family
- Sun StorEdge L180 tape library
- Sun StorEdge L700 tape library
- Sun StorEdge L5500 tape library
- Sun StorEdge L6000 tape library
(Utilization of the Sun StorEdge L180 and
L700 tape libraries may be limited by the number of SCSI
host bus adapters and buses available for connection to the
server.)
|
| Software |
| Operating
system |
Solaris[tm]
8 (2/02) Operating Environment or later |
| Languages |
C, C++,
Pascal, Fortran, Java |
| Networking |
ONC, NFS,
TCP/IP, SunLink OSI, MHS, IPX SPX |
| System monitoring |
Sun
Management Center |
| System and
network management |
- Solaris Bandwidth Manager
- Solaris Resource Manager
- Sun Management Center
- Sun Remote System Control
- Sun Cluster
- Solaris PC NetLink
- Solaris WebStart
- Solaris Web Start Wizards
- Solstice Backup
|
| Console
Options |
| Monitor |
Optional:
Sun monitors from 1995 and later (17-, FP18-, 21-, and
24-inch monitors) |
| Frame buffer |
Sun PGX64
8/24-bit |
| Keyboard and
mouse |
USB keyboard
and mouse |
| PCI I/O
options |
Gigabit
Ethernet, 10/100-MBps Ethernet, dual-channel FC-AL disks,
single-channel FC-AL, Quad FastEthernet, token ring, FDDI,
ATM-155, ATM-622, high-speed serial, Ultra SCSI with
10/100-MBps Ethernet, dual-channel single-ended Ultra SCSI,
dual-channel differential Ultra SCSI |
| Power
Supplies |
| One
required, two for redundancy, each with independent power
cord |
| Maximum AC
input |
1440 W per
power supply |
| Maximum DC
output |
1184 W per
power supply |
| Environment |
| AC power |
100-240 VAC,
47-63 Hz, 0.895 KVA |
| Operating |
5º C to 35º
C (41º F to 95º F), 20% to 80% relative temperature
humidity, noncondensing, 27º C maximum wet bulb |
| Nonoperating |
-20º C to
60º C (-4º F to 140º F), 5% to 95% relative temperature
humidity, noncondensing |
| Regulations |
| Meets
or exceeds the following requirements: |
| Safety |
UL 1950, CB
Scheme IEC 950 (CE Mark), CSA C22.2 950 (from UL), TUV EN
60950 |
| RFI/EMI |
Class A:
- Australia/New Zealand AS/NZ 3548
- Industry Canada ICES-003
- European Community EN55022/CISPR22
- Japan VCCI
- Taiwan CNS 13438
- US FCC 47CFR15.B
|
| Immunity |
EN55024,
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-8, EN61000-4-11, IEC 61000-3-2, IEC
61000-3-3 |
| X-ray |
U.S. DHHS
21CFR Subchapter J, PTB German X-ray decree |
| Dimensions
and Weights |
| Height |
5 RU, 222 mm
(8.75 in.) |
| Width |
446 mm (17.5
in.) |
| Depth |
610 mm (24.0
in.) |
| Weight |
Minimum:
35.8 kg (79 lb.)
Fully configured: 44 kg (97 lb.) |
| Power cords |
4.0 m (13.13
ft.) |
| Rack |
Fits into a
standard 19-in. wide rackmount kit that complies with
EIA-310-D-1992 standard or a 72-in. high Sun StorEdge rack,
which supports six Sun Fire V480 servers. |